• Users Online: 567
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2022  |  Volume : 10  |  Issue : 3  |  Page : 114-117

Foldscope: Diagnostic accuracy and feasibility of its use in national malaria control program


1 Department of Microbiology, AIIMS, Bhopal, Madhya Pradesh, India
2 Department of CFM, AIIMS, Bhopal, Madhya Pradesh, India
3 Department of Pathology, AIIMS, Bhopal, Madhya Pradesh, India
4 Department of Medicine, AIIMS, Bhopal, Madhya Pradesh, India

Correspondence Address:
Dr. Sagar Khadanga
Department of Medicine, AIIMS, Saket Nagar, Bhopal, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmau.jmau_103_20

Rights and Permissions

Background: Malaria has been an important public health all over the globe. Although conventional light microscopy is the gold standard of diagnosis, light microscopes are heavy, fragile, costly, and electricity dependent. Rapid diagnostic tests (RDTs) have become more popular but perform badly in temperate climate. This is because the RDT kits require maintenance of cold chain for its optimal use. In this regard, there is a recent interest in handheld malaria microscopy at the point of care in the field setting. Foldscopes are cheap, handy, nonfragile, and use mobile camera for illumination. The purpose of the study was to find whether foldscope can be used in the national vector borne disease control program (NVBDCP) in India. Methods: Ten laboratory technicians were trained in identifying malaria parasites using foldscope and their mobiles. Later, they were provided with unassembled foldscope to document their test results for the preidentified malaria slides. The blood smears were stained as per the protocol of NVBDCP. The report of the index test (foldscope microscopy) was compared with the reference test (conventional microscopy). Results: The sensitivity and specificity of the index test was found to be 13.3% (6.257–26.18), specificity of 97.78% (88.43–99.61), positive predictive value 85.71% (48.69–97.43), and negative predictive value 53.01% (42.38–63.38). The devise failure rate and test failure rate were 20% and 11.7%. The kappa agreement between the index and reference microscopy was only 11% and the McNemar P < 0.01. Conclusion: The ×400 foldscope at its present magnification and illumination cannot be utilized in the field under NVBDCP.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed189    
    Printed6    
    Emailed0    
    PDF Downloaded20    
    Comments [Add]    

Recommend this journal