• Users Online: 74
  • Print this page
  • Email this page
 
ORIGINAL ARTICLE
Ahead of Print

ImageJ-FIJI-Assisted estimation of intestinal layers' volume: Study in Jejunum–Ileum of rats


 Department of Histology and Cell Biology, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia

Correspondence Address:
Rina Susilowati,
Department of Histology and Cell Biology, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Sekip, Yogyakarta 55281
Indonesia
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/jmau.jmau_53_22

Background: Studies in the digestive tract often required precision quantification of intestinal volume to observe the effect of certain intervention/condition. Application of stereological methods could bring unbiased and accurate results but commercially computer-assisted systems are not widely available. ImageJ-FIJI is an open source software, which could become an alternative choice in the stereological measurement process. Aim: This study describes simple stereological quantification methods during volume estimation of jejunum-ileum intestinal layers of the rats using a light microscope and ImageJ-FIJI stereological tool. Material and Methods: Six 3-months old male Sprague-Dawley rats were terminated and jejunum-ileum was harvested after perfusion. After removal of intestinal luminal content, whole jejunum-ileum weight was measured. The organ was sampled as 6-10 slabs of 1 cm length in a systematic uniformed random sampling manner. Slabs were cut longitudinally at random angles before flattened and put on filter papers for subsequent tissue processing into 2-3 paraffin blocks. One section of 3 μm thick was sampled from each block, stained using toluidine blue and documented using a light microscope connected to a microstepper apparatus. The volume of the intestinal layers was estimated using a point-counting grid on Image J-FIJI software. Result: We compared two sets of counting methods i.e. minimal counting (MC) and rigorous counting (RC) approaches that differ in their respective a/p value. Quantification using RC approach resulted in significantly higher estimated volume of tunica submucosa and tunica muscularis while having more preferable stereological accuracy parameters (CE<5% & CV<10%). Conclusion: Although it required longer counting time, rigorous approaches resulted in higher accuracy while still within the range of rule of thumb criteria of 0.2 < CE2/CV2 < 0.5.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Wicaksono SA
    -  Sumiwi YA
    -  Paramita DK
    -  Susilowati R
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed213    
    PDF Downloaded11    

Recommend this journal